Specifications Table for EHSX-D / ERGA04-08DV

EHSX04P50DA / ERGA04DAV3 EHSX04P30DA / ERGA04DAV3 EHSX04P50DA7 / ERGA04DAV3 EHSX08P30DA / ERGA06DAV3 EHSX08P50DA / ERGA06DAV3 EHSX08P50DA7 / ERGA06DAV3 EHSX08P50DA / ERGA08DAV3A EHSX08P30DA / ERGA08DAV3A EHSX08P30DA / ERGA08DAV3 EHSX08P50DA / ERGA08DAV3 EHSX08P50DA7 / ERGA08DAV3
Indoor unit EHSX04P50D EHSX04P30D EHSX04P50DA7 EHSX08P30D EHSX08P50D EHSX08P50DA7 EHSX08P50D EHSX08P30D EHSX08P30D EHSX08P50D EHSX08P50DA7
Kapacitet grejanja Nom. kW 4.30 (1), 4.60 (2) 4.30 (1), 4.60 (2) 4.30 (1), 4.60 (2) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2)
Kapacitet hlađenja Nom. kW 5.56 (1), 4.37 (2) 5.56 (1), 4.37 (2) 4.86 (1), 4.52 (2) 5.96 (1), 4.87 (2) 5.96 (1), 4.87 (2) 5.96 (1), 5.09 (2) 5.35 (2), 6.25 (1) 5.35 (2), 6.25 (1) 6.25 (1), 5.35 (2) 6.25 (1), 5.35 (2) 6.25 (1), 5.44 (2)
Apsorbovana snaga Grejanje Nom. kW 0.850 (1), 1.26 (2) 0.850 (1), 1.26 (2) 0.840 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2)
  Hlađenje Nom. kW 0.940 (1), 1.14 (2) 0.940 (1), 1.14 (2) 0.810 (1), 1.36 (2) 1.06 (1), 1.33 (2) 1.06 (1), 1.33 (2) 1.06 (1), 1.55 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.73 (2)
Heat up time from 10°C to 50°C hr   1h31min   1h31min 2h57min       1h31min 2h57min  
COP 5.10 (1), 3.65 (2) 5.10 (1), 3.65 (2) 5.10 (1), 3.65 (2) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 3.50 (2), 4.60 (1) 3.50 (2), 4.60 (1) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2)
EER 5.94 (1), 3.84 (2) 5.94 (1), 3.84 (2) 5.98 (1), 3.32 (2) 5.61 (1), 3.67 (2) 5.61 (1), 3.67 (2) 5.61 (1), 3.28 (2) 3.54 (2), 5.40 (1) 3.54 (2), 5.40 (1) 5.40 (1), 3.54 (2) 5.40 (1), 3.54 (2) 5.40 (1), 3.14 (2)
Zagrevanje vode za domaćinstvo Opis proizvoda Deklarisani profil opterećenja   XL L XL L XL XL XL L L XL XL
  Prosečni klimatski uslovi Klasa energetske efikasnosti zagrevanja vode   A A A A A A   A A A A
Beleške Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) (1) - Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) (1) - Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C) (1) - Uslov 1: hlađenje Ta 35°C - LWE 18℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 35 °C (DT = 5 °C)
  Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) (2) - Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) (2) - Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C) (2) - Uslov 2: hlađenje Ta 35°C - LWE 7℃ (DT = 5°C); grejanje Ta DB/WB 7 °C/6 °C - LWC 45℃ (DT = 5 °C)
Grejanje prostora Izl. voda pri prosečnim klimatskim usl. 55°C Opšti podaci SCOP     3.26   3.26 3.26   3.27 3.27 3.32 3.32  
      Klasa sezonske efikasnosti grejanja prostora     A++   A++ A++   A++ A++ A++ A++  
  Izl. voda pri prosečnim klimatskim usl. 35°C Opšti podaci SCOP     4.48   4.47 4.47   4.56 4.56 4.56 4.56  
      Klasa sezonske efikasnosti grejanja prostora     A++   A++ A++   A++ A++ A++ A++